Product name:MGR-DT2240EG

Product overview:

TAG:  MAGER MGR-DT SERIES / SOLID STATE MODULE / SINGLE PHASE / VOLTAGE REGULATOR / COMPLETE ELECTRICAL ISOLATION
Control Signal:  E: CON 0-5V; F: CON 0-10V; G: CON 4-20mA; H: CON 1-5V
*(E, F, H types can be controlled by the manual control circuit, G type cannot be adjusted with the potentiometer)
Load Voltage:  220VAC / 380VAC
Load Current:  Enhanced Type--15A, 35A, 55A, 75A, 120A, 150A, 190A, 240A, 290A, 350A; Ordinary type--10A, 25A, 40A; Half-Wave Type--10A, 25A, 50A
Dimensions & Mounting:  105mm*74mm*33mm; Panel mount solid state module with plastic cover, metal base and screw terminals

Content us Return list Download PDF

Product introduction



MGR-DT2240EG

FULL ISOLATION SINGLE PHASE AC VOLTAGE REGULATOR MODULE
(used to name as " DTY-H220D40EG " or " SCR-2240EG " )

Product Image - MGR DT 2240 EG

FULL ISOLATION SINGLE PHASE AC VOLTAGE REGULATOR MODULE
(DT)

● The full isolation single phase AC voltage regulator module (hereinafter referred to as the single phase voltage regulator module DT) integrates the synchronous transformer, the phase detection circuit, the phase-shift trigger circuit and the thyristor output circuit. The trigger angle (firing angle) of the thyristor can be controlled by changing the control voltage, that is, to regulate the single phase AC output voltage. According to the different types of the thyristor, the single phase voltage regulator module DT can be divided into three types: Ordinary Type (one TRIAC as the output component), Enhanced Type (a pair of reverse-parallel SCR as the output component) and Half-wave Type (one SCR as the output component). According to the rated voltage of single phase AC load, the single phase voltage regulator module DT can be divided into 220V type and 380V type. According to different control signals, the single phase voltage regulator module DT can be divided into four types: E, F, G, and H types. The following is the specification model table (Note: The current grade in this table is the maximum rms current of the internal thyristor of the module).
● For convenience of explanation, the following introduces with the 0~5V control signal as a standard (Model: DT):
● ① and ② ports are the output terminals of the module (i.e., the two poles of the thyristor inside the module). ① and ② ports of the enhanced and the ordinary type have no polarity. The anode of the SCR thyristor inside the half-wave type module is connected to the ① port, and the cathode is connected to the ② port.
● ③ and ④ ports are the synchronous transformer primary inside the module, and the specification can be divided into 220VAC type and 380VAC type: 220VAC type can be used into the power grid at the range of 165-240VAC, 380VAC type can be used into the power grid at the range of 285-420VAC. ③ and ④ ports have no polarity.
● COM port is the internal common ground terminal, CON port is the control terminal, and the +5V port is the power supply generated inside the module only for the manual control of potentiometer. The strong current part (①, ②, ③, and ④ ports) and the weak current part (+5V, CON, and COM ports) are fully isolated. The application circuit is shown below:

Dimensions - MGR DT 2240 EG




EG Type: CON1 0-5V
CON2 4-20mA
F Type: CON 0-10VH Type: CON 1-5V
Ordinary TypeLoad 220V10AMGR-DT2210EGMGR-DT2210FMGR-DT2210H
25AMGR-DT2225EGMGR-DT2225FMGR-DT2225H
40AMGR-DT2240EGMGR-DT2240FMGR-DT2240H
Load 380V10AMGR-DT3810EGMGR-DT3810FMGR-DT3810H
25AMGR-DT3825EGMGR-DT3825FMGR-DT3825H
40AMGR-DT3840EGMGR-DT3840FMGR-DT3840H
Enhanced TypeLoad 220V15AMGR-DT2215EGMGR-DT2215FMGR-DT2215H
35AMGR-DT2235EGMGR-DT2235FMGR-DT2235H
55AMGR-DT2255EGMGR-DT2255FMGR-DT2255H
75AMGR-DT2275EGMGR-DT2275FMGR-DT2275H
120AMGR-DT22120EGMGR-DT22120FMGR-DT22120H
150AMGR-DT22150EGMGR-DT22150FMGR-DT22150H
190AMGR-DT22190EGMGR-DT22190FMGR-DT22190H
240AMGR-DT22240EGMGR-DT22240FMGR-DT22240H
290AMGR-DT22290EGMGR-DT22290FMGR-DT22290H
350AMGR-DT22350EGMGR-DT22350FMGR-DT22350H
Load 380V15AMGR-DT3815EGMGR-DT3815FMGR-DT3815H
35AMGR-DT3835EGMGR-DT3835FMGR-DT3835H
55AMGR-DT3855EGMGR-DT3855FMGR-DT3855H
75AMGR-DT3875EGMGR-DT3875FMGR-DT3875H
120AMGR-DT38120EGMGR-DT38120FMGR-DT38120H
150AMGR-DT38150EGMGR-DT38150FMGR-DT38150H
190AMGR-DT38190EGMGR-DT38190FMGR-DT38190H
240AMGR-DT38240EGMGR-DT38240FMGR-DT38240H
290AMGR-DT38290EGMGR-DT38290FMGR-DT38290H
350AMGR-DT38350EGMGR-DT38350FMGR-DT38350H
Half-Wave TypeLoad 220V10AMGR-DT2210XEGMGR-DT2210XFMGR-DT2210XH
25AMGR-DT2225XEGMGR-DT2225XFMGR-DT2225XH
50AMGR-DT2250XEGMGR-DT2250XFMGR-DT2250XH
Load 380V10AMGR-DT3810XEGMGR-DT3810XFMGR-DT3810XH
25AMGR-DT3825XEGMGR-DT3825XFMGR-DT3825XH
50AMGR-DT3850XEGMGR-DT3850XFMGR-DT3850XH

Wiring diagram and Waveform meaning - MGR DT series

Related technical specifications and precautions
● The phase applied to the load through ① and ② ports must be consistent with the phase of ③ and ④ ports, otherwise the device will be out of control. And the frequency of the power grid must be 50 Hz.
● CON must be positive relative to COM, and if the polarity is opposite, the output terminal will be out of control (fully open or fully closed). When the control terminal CON changes from 0V to 5V, the voltage on the AC load can be adjusted from 0V to the maximum value (for resistive loads). When the control voltage on CON is around 0V~0.8V (Fully-closed Region), the control signal can reliably shut down the output of the module. When the control voltage on CON is around 0.8V~4.6V (Adjustable Region), the conduction angle α decreases linearly from 180° to 0° as the control voltage increases, and the voltage on the AC load increases from 0V to the maximum value. When the control voltage on CON is around 4.6V~5V (Full-open Region), the voltage on the AC load is the maximum value (close to the power grid voltage).
● The input impedance between CON and COM is divided into E, F and H type (the impedance of these three types are greater than or equal to 30KΩ), and G type (the impedance is 250Ω). The +5V voltage signal is only provided for the manual potentiometer (the selected resistance is between 2~10KΩ), not for other uses. Note: The G type (4~20mA as control signal) cannot be manually adjusted by the potentiometer, so the +5V port is useless for the G type.
● The speed control of the single phase AC asynchronous motor should be adjusted by the frequency converter, while the single phase voltage regulation module can only be applied to fan motors and pump motors where the requirements are not high.
● It is not possible to use three single phase voltage regulator modules to regulate the three phase load on the three phase power grid.
● The insulation voltage between the strong current part, the weak current part, and the module backplane is greater than 2000VAC.
● The heat of the whole module = Actual load current (Amps) * 1.5 W/Amps. Customers can select MG-L, MG-H series heat sink according to actual needs.
● For specifications and precautions for selecting the current grade, device protection, etc., please refer to the instruction of single phase AC solid state relays.

Tips
1) When selecting the rated current of the solid state relay/solid state module, please consider the corresponding Derating Factor .
2) You can visit Resource to view and download files.
3) You can visit Products to view and learn about other products.
4) You can visit Information to view and learn about solid state relays/solid state modules knowledge.
5) You can also visit Help , or Contact us to get more support.