E3F Series
Amplifier Separate Type Photoelectric Sensor
E3F series amplifier separate type photoelectric sensor is a cylindrical shape photoelectric sensor with 1ms turn-on delay. The detection methods of the E3F series are thru-beam, retro-reflection, and diffuse-reflection. E3F series photoelectric sensor adopts the full-threaded design, which reduces the installation dimensions, and is easy to install, and it can be clamped directly with a wrench. E3F series photoelectric sensors use high-quality chips, which have the advantages of long life and high reliability, and can adapt to complex working environments. E3F series photoelectric sensors are equipped with power reverse protection, short-circuit protection, current overload protection, etc., and can be directly connected with PLC device. The operating status of the sensor can be directly observed through the red LED, E3F series photoelectric sensors are IP67 protected (IEC standard). E3F series photoelectric sensors also have a enhanced shell strength and improved wire breakage countermeasures. Depending on the control output, photoelectric sensors can be divided into NPN type (Type N), PNP type (Type P), AC type (Type A), and Relay type (Type J). For more information about the proximity sensors, please visit "What is Photoelectric Sensors".
ImageName
How to order
Features
● Components using high-quality chips
● Reverse power supply protection, short circuit protection, and current overload protection
● Long life and high reliability, high environmental adaptability
● Directly connect to PLC
● The red LED shows the operating status of the sensor
● Full-threaded design reduces mounting dimensions and allows for direct wrench clamping
● Enhanced shell strength, and improved wire breakage countermeasures
● IP67 protection structure (IEC specification)
● Please read "Precautions for Photoelectric Sensors" before use
Parameters
● Turn-on Delay: 1.5ms
● Light Source: Infrared light 660nm
● Detection Method: Thru-beam, Retro-reflection, Diffuse-reflection
● Supply Voltage: DC type — 12-24VDC (6-36VDC) with voltage pulsation (p-p) below 10%; AC type — 110-220VAC (90-250VAC), 50/60Hz
● Current Consumption Type N.P — under 20mA; Type A — under 1.7mA
● Control Output: Type N.P – below 300mA; Type A – below 400mA; Type J – below 2A (contact life above 100,000 cycles)
● Circuit Protection: N.P.D type — Reverse power supply protection, surge absorption, short-circuit protection; A Type — Surge absorption
● Ambient Temperature (operating, storage): -30-+65°C (non-freezing, non-condensing)
● Ambient Humidity (operating, storage): 35-95%RH
● Insulation Impedance: Above 50 MΩ (between the charging section and the housing, using a DC500 megohmmeter)
● Withstanding Voltage (1min): 1000VAC, 50/60Hz (between charging section and case)
● Temperature Effect: If the temperature range is -30 to +65℃, the sensing distance is within ±15% of the detection distance at +23℃; if the temperature range is -25 to +60℃, the sensing distance is within ±10% of the detection distance at +23℃.
● Voltage Effect: If the voltage range is within ±15% of the rated supply voltage, the sensing distance is within ±10% of the detection distance at the rated supply voltage.
● Protective Structure: IP67 (IEC standard)
● Material: Housing — nickel plated brass/ ABS; Detection surface (Lens) — PMMA
Datasheet
E3F Series Photoelectric Sensors Dimensions M8x1 M12x1 Mounting Methods Thru-beam Diffuse-reflection Retro-reflection Thru-beam Models DC NPN NO E3F01-2DN1-2L E3F1-DS5C4 E3F1-R1C1 E3F1-3DN1-3L NC E3F01-2DN2-2L E3F1-DS5C2 E3F1-R1C2 E3F1-3DN2-3L NO+NC PNP NO E3F01-2DP1-2L E3F1-DS5P1 E3F1-R1P1 E3F1-3DP1-3L NC E3F01-2DP2-2L E3F1-DS5P2 E3F1-R1P2 E3F1-3DP2-3L NO+NC NPN/PNP/NO/NC AC 2-wires NO NC 3-wires Relay Outputs Detection Distance 2m±10% 5cm±10% 1m±10% 3m±10% Standard Sensing Object Opaque Transparent / Opaque Opaque Opaque Detection Distance adjustment Fixed Fixed Sensitivity regulator Fixed Response Frequency 1ms 1ms 1ms 1ms Outline Dimension Drawing Figure1 Figure2 Dimensions M18x1 Mounting Methods Diffuse-reflection Retro-reflection Thru-beam Models DC NPN NO E3F-DS10C4 E3F-DS30C4 E3F-R2C1 E3F-5DN1-5L NC E3F-DS10C2 E3F-DS30C2 E3F-R2C2 E3F-5DN2-5L NO+NC E3F-DS10C3 E3F-DS30C3 E3F-R2C3 E3F-5DN3-5L PNP NO E3F-DS10P1 E3F-DS30P1 E3F-R2P1 E3F-5DP1-5L NC E3F-DS10P2 E3F-DS30P2 E3F-R2P2 E3F-5DP2-5L NO+NC E3F-DS10P3 E3F-DS30P3 E3F-R2P3 E3F-5DP3-5L NPN/PNP/NO/NC E3F-DS10X E3F-DS30X E3F-R2X E3F-5DX-5L AC 2-wires NO E3F-DS10Y1 E3F-DS30Y1 E3F-R2Y1 E3F-5DY1-5LY NC E3F-DS10Y2 E3F-DS30Y2 E3F-R2Y2 E3F-5DY2-5LY 3-wires Relay Outputs Detection Distance 10cm±10% 10-30cm±10% 2m±10% 5m±10% Standard Sensing Object Transparent / Opaque Transparent / Opaque Opaque Opaque Detection Distance adjustment Fixed Sensitivity regulator Sensitivity regulator Fixed Response Frequency 1ms 1ms 1ms 1ms Outline Dimension Drawing Figure3 Dimensions M18x1 Mounting Methods Diffuse-reflection Retro-reflection Thru-beam Models DC NPN NO E3F3-D11 E3F3-D12 E3F3-R11 E3F3-T11 NC E3F3-D61 E3F3-D62 E3F3-R61 E3F3-T61 NO+NC PNP NO E3F3-D31 E3F3-D32 E3F3-R31 E3F3-T31 NC E3F3-D81 E3F3-D82 E3F3-R81 E3F3-T81 NO+NC NPN/PNP/NO/NC AC 2-wires NO NC 3-wires Relay Outputs Detection Distance 10cm±10% 10-30cm±10% 3m±10% 5m±10% Standard Sensing Object Transparent / Opaque Transparent / Opaque Opaque Opaque Detection Distance adjustment Sensitivity regulator Sensitivity regulator Sensitivity regulator Fixed Response Frequency 1ms 1ms 1ms 1ms Outline Dimension Drawing Figure4 Dimensions M30x1.5 Mounting Methods Diffuse-reflection Retro-reflection Thru-beam Models DC NPN NO E3F3-DS70C1 E3F3-R4C1 E3F3-10DN1-10L NC E3F3-DS70C2 E3F3-R4C2 E3F3-10DN2-10L NO+NC E3F3-DS70C3 E3F3-R4C3 E3F3-10DN3-10L PNP NO E3F3-DS70P1 E3F3-R4P1 E3F3-10DP1-10L NC E3F3-DS70P2 E3F3-R4P2 E3F3-10DP2-10L NO+NC E3F3-DS70P3 E3F3-R4P3 E3F3-10DP3-10L NPN/PNP/NO/NC AC 2-wires NO E3F-DS70Y1 E3F3-R4Y1 E3F-10DY1-10LY NC E3F-DS70Y2 E3F3-R4Y2 E3F-10DY2-10LY 3-wires Relay Outputs Detection Distance 70cm±10% 4m±10% 10m±10% Standard Sensing Object Transparent / Opaque Opaque Opaque Detection Distance adjustment Sensitivity regulator Sensitivity regulator Fixed Response Frequency 1ms 1ms 1ms Outline Dimension Drawing Figure5
Dimensions & wiring diagram
Updates
2023-10-27
Upload page data and generate pages.
Get in touch with us now!
Please take a minute or two to complete this simple form to get reply in 24 hours, thank you!
*Please check the trash box of your mailbox, if you do not receive our email.