Location: Home > Product  

CDD series amplifier separate type photoelectric sensor

CDD series
amplifier separate type photoelectric sensor

CDD series amplifier separate type photoelectric sensor is a cylindrical shape photoelectric sensor with 1ms turn-on delay. The detection method of the CDD series is diffuse-reflection. CDD series photoelectric sensor adopts the full-threaded design, which reduces the installation dimensions, and is easy to install, and it can be clamped directly with a wrench. CDD series photoelectric sensors use high-quality chips, which have the advantages of long life and high reliability, and can adapt to complex working environments. CDD series photoelectric sensors are equipped with power reverse protection, short-circuit protection, current overload protection, etc., and can be directly connected with PLC device. The operating status of the sensor can be directly observed through the red LED, CDD series photoelectric sensors are IP67 protected (IEC standard). CDD series photoelectric sensors also have a enhanced shell strength and improved wire breakage countermeasures. Depending on the control output, photoelectric sensors can be divided into NPN type (Type N), PNP type (Type P), AC type (Type A), and Relay type (Type J). For more information about the proximity sensors, please visit "What is Photoelectric Sensors".

  • CDD

ImageName

Model
Data&Sheet
Dimensions
Updates

How to order


Features


● Components using high-quality chips

● Reverse power supply protection, short circuit protection, and current overload protection

● Long life and high reliability, high environmental adaptability

● Directly connect to PLC

● The red LED shows the operating status of the sensor

● Full-threaded design reduces mounting dimensions and allows for direct wrench clamping

● Enhanced shell strength, and improved wire breakage countermeasures

● IP67 protection structure (IEC specification)

● Please read "Precautions for Photoelectric Sensors" before use

Parameters


● Turn-on Delay: 1.5ms

● Light Source: Infrared light 660nm

● Detection Method: Diffuse-reflection

● Supply Voltage: DC type — 12-24VDC (6-36VDC) with voltage pulsation (p-p) below 10%; AC type — 110-220VAC (90-250VAC), 50/60Hz

● Current Consumption Type N.P — under 20mA; Type A — under 1.7mA

● Control Output: Type N.P – below 300mA; Type A – below 400mA; Type J – below 2A (contact life above 100,000 cycles)

● Circuit Protection: N.P.D type — Reverse power supply protection, surge absorption, short-circuit protection; A Type — Surge absorption

● Ambient Temperature (operating, storage): -30-+65°C (non-freezing, non-condensing)

● Ambient Humidity (operating, storage): 35-95%RH

● Insulation Impedance: Above 50 MΩ (between the charging section and the housing, using a DC500 megohmmeter)

● Withstanding Voltage (1min): 1000VAC, 50/60Hz (between charging section and case)

● Temperature Effect: If the temperature range is -30 to +65℃, the sensing distance is within ±15% of the detection distance at +23℃; if the temperature range is -25 to +60℃, the sensing distance is within ±10% of the detection distance at +23℃.

● Voltage Effect: If the voltage range is within ±15% of the rated supply voltage, the sensing distance is within ±10% of the detection distance at the rated supply voltage.

● Protective Structure: IP67 (IEC standard)

● Material: Housing — nickel plated brass/ ABS; Detection surface  (Lens)  — PMMA

Datasheet


CDD Series Photoelectric Sensors
DimensionsM18x1
Mounting MethodsDiffuse-reflection
ModelsDCNPNNO
NC
NO+NCCDD-11N(40N)
PNPNO
NC
NO+NCCDD-11P(40P)
NPN/PNP/NO/NC
AC2-wiresNO
NC
3-wires
Relay Outputs
Detection Distance10-30cm±10%
Standard Sensing ObjectOpaque
Detection Distance adjustmentSensitivity regulator
Response Frequency1ms
Outline Dimension DrawingFigure1

Dimensions & wiring diagram


CDD series, dimensions and wiring diagram, Photoelectric Sensor